Large LCD screen, touch operation
Temperature detection range: -50 to 150 °C
Temperature detection accuracy: ±0.5 F.S
Temperature detection resolution: 0.1 °C
Water content detection range: 4 to 80%
Moisture detection points: 6
Tree species classification: 4
Fan commutation time: 2 hours
Fan commutation stop time: 3 minutes
Fan start interval: 15 seconds
Volume: 420 × 230 × 130 (mm)
Power source: 220V, 50HZ AC voltage
M800B automatic wood drying kiln control instrument utilizes a good electrical technology manufacturing technology, and has accumulated a good solution in the wood drying kiln control system with more than ten years of experience. Its compact shape, complete functions, accurate measurement, stable and reliable.
Standard configuration parameters
Power supply 24±20% Vac/dc 0-60Hz
Power 40W
Operating temperature 0 to 40 ° C (CPU) -20 to 50 ° C (amplifier)
Kiln temperature 0-130 ° C
Wood moisture content 6-90% @25°C
Balanced humidity EMC 4-30% @25°C
Number of wood probes 6
Temperature probe number 2
EMC probe number 2
Wood group 4
Switching output 8 relay output, 5A-250VAC
Steaming, heating and damper switching control; fan forward and reverse control.
Analog output: 1 channel and power supply insulated 0-10V output for controlling fan speed
Pulse output: control the heating, damper and steaming of the electric control valve
Digital interface: RS232, RS485
YDM600 wood drying kiln controller
1.1 road temperature detection display; 1 channel wet bulb detection display;
2.6 points wood moisture rate inspection, unreasonable measurement points can be eliminated, automatically calculate the average moisture content;
3. Heating, tidal, and steaming provide automatic (manual) on/off control;
4. Provide parameter setting and control functions such as temperature/humidity threshold, advanced shut-off valve, over-temperature alarm, etc.
5. The fan has 2 hours of automatic commutation (time course using LED light bar indication), each fan delay start and manual control.
Temperature detection range: -50 to 150 °C
Temperature detection accuracy: ±0.5 F.S
Temperature detection resolution: 0.1 °C
Water content detection range: 4 to 80%
Moisture detection points: 6
Tree species classification: 4
Fan commutation time: 2 hours
Fan commutation stop time: 3 minutes
Fan start interval: 15 seconds
Volume: 420 × 230 × 130 (mm)
Power source: 220V, 50HZ AC voltage